Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

ZHOU Yong-gang, HUANG Sheng, GU Li, WANG Bin, ZHANG Guo-qing, LOU Zi-yang. Determination of mangiferin and neo-mangiferin in Rhizoma Anemarrhenae by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2005, (2): 99-102.
Citation: ZHOU Yong-gang, HUANG Sheng, GU Li, WANG Bin, ZHANG Guo-qing, LOU Zi-yang. Determination of mangiferin and neo-mangiferin in Rhizoma Anemarrhenae by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2005, (2): 99-102.

Determination of mangiferin and neo-mangiferin in Rhizoma Anemarrhenae by HPLC

  • Objective To establish the method for determination of mangiferin and neo-mangiferin in Rhizoma Anemarrhenae. Method The content was determined by HPLC. A Zorbax Eclipse XDB-C18 column(4.6mm×250mm,5μm) with a grient mobile phase composed of 25 mmol/L dihydrophosphate potassium and acetonitrile were used. The detection wavelength was 257 nm and the flow rate was 1.0mL/min. Results The calibration curves of mangiferin were linear between 14.2-568.5μg/mL(r=0.9999), the neo-mangiferin were 14.8-590.5μg/mL. The withinday precision RSD was both less than 4.5% and the interday precision RSD was less than 3.9%. Conclusion The method is simple, rapid, accurate and is suitable for the determination of mangiferin and neo-mangiferin.
  • 加载中
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2891) PDF downloads(472) Cited by()

Related
Proportional views

Determination of mangiferin and neo-mangiferin in Rhizoma Anemarrhenae by HPLC

Abstract: Objective To establish the method for determination of mangiferin and neo-mangiferin in Rhizoma Anemarrhenae. Method The content was determined by HPLC. A Zorbax Eclipse XDB-C18 column(4.6mm×250mm,5μm) with a grient mobile phase composed of 25 mmol/L dihydrophosphate potassium and acetonitrile were used. The detection wavelength was 257 nm and the flow rate was 1.0mL/min. Results The calibration curves of mangiferin were linear between 14.2-568.5μg/mL(r=0.9999), the neo-mangiferin were 14.8-590.5μg/mL. The withinday precision RSD was both less than 4.5% and the interday precision RSD was less than 3.9%. Conclusion The method is simple, rapid, accurate and is suitable for the determination of mangiferin and neo-mangiferin.

ZHOU Yong-gang, HUANG Sheng, GU Li, WANG Bin, ZHANG Guo-qing, LOU Zi-yang. Determination of mangiferin and neo-mangiferin in Rhizoma Anemarrhenae by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2005, (2): 99-102.
Citation: ZHOU Yong-gang, HUANG Sheng, GU Li, WANG Bin, ZHANG Guo-qing, LOU Zi-yang. Determination of mangiferin and neo-mangiferin in Rhizoma Anemarrhenae by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2005, (2): 99-102.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return