Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

SUN Wei-zhang, YU Bo-tao, JIANG Yan, ZHOU Mao-zai. Determination of glutathione and oxidized glutathione by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2012, 30(4): 305-306,315.
Citation: SUN Wei-zhang, YU Bo-tao, JIANG Yan, ZHOU Mao-zai. Determination of glutathione and oxidized glutathione by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2012, 30(4): 305-306,315.

Determination of glutathione and oxidized glutathione by HPLC

  • Received Date: 2012-03-12
  • Rev Recd Date: 2012-05-21
  • Objective To establish a method to determine GSH and GSSG by HPLC. Method The analytical column was Hypersil C18. The mobile phase consisted of 25m mol/L KH2PO4 (pH2.5):tetrahydrofuran (100:1). The flow rate was 1.0 ml/min. Column temperature was 30 ℃ and the detective wavelength was 230 nm. Result The calibration curve of GSH was linear within the range of 3.12 μg/ml~2490.0 μg/ml (r=0.9999) and the average recovery was 101.84%. The calibration curve of GSSG was linear within the range of 3.25 μg/ml~975.0 μg/ml (r=0.9999) and the average recovery was 97,84%. Conclusion The method was proved to be reliable and accurate,which could be used to determinate GSH and GSSG simultaneously.
  • 加载中
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(3304) PDF downloads(360) Cited by()

Related
Proportional views

Determination of glutathione and oxidized glutathione by HPLC

Abstract: Objective To establish a method to determine GSH and GSSG by HPLC. Method The analytical column was Hypersil C18. The mobile phase consisted of 25m mol/L KH2PO4 (pH2.5):tetrahydrofuran (100:1). The flow rate was 1.0 ml/min. Column temperature was 30 ℃ and the detective wavelength was 230 nm. Result The calibration curve of GSH was linear within the range of 3.12 μg/ml~2490.0 μg/ml (r=0.9999) and the average recovery was 101.84%. The calibration curve of GSSG was linear within the range of 3.25 μg/ml~975.0 μg/ml (r=0.9999) and the average recovery was 97,84%. Conclusion The method was proved to be reliable and accurate,which could be used to determinate GSH and GSSG simultaneously.

SUN Wei-zhang, YU Bo-tao, JIANG Yan, ZHOU Mao-zai. Determination of glutathione and oxidized glutathione by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2012, 30(4): 305-306,315.
Citation: SUN Wei-zhang, YU Bo-tao, JIANG Yan, ZHOU Mao-zai. Determination of glutathione and oxidized glutathione by HPLC[J]. Journal of Pharmaceutical Practice and Service, 2012, 30(4): 305-306,315.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return