Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

Yuan Li-xia, Wang Hong. Method for quality control of Cortex Phellocienciri in Niuhuang Yijin tablets[J]. Journal of Pharmaceutical Practice and Service, 2008, (2): 141-142,155.
Citation: Yuan Li-xia, Wang Hong. Method for quality control of Cortex Phellocienciri in Niuhuang Yijin tablets[J]. Journal of Pharmaceutical Practice and Service, 2008, (2): 141-142,155.

Method for quality control of Cortex Phellocienciri in Niuhuang Yijin tablets

  • Objective: To develop a method to determine the content of berberine hydrochlide in Niuhuang Yijin tablets to guarantee the quality of it. Methods: The determination was performed on Kromasil C18 column(4.6×250 mm,5 μm) with the mobile phase of CH3CN(0.05 mol/L)-KH2PO4(pH 3.0±0.05,0.025 mol/L)-sodium dodecylsulfonate.The detection wavelength was 348nm. Results: The correlation coefficients was 0.999 3 when the linear range was from 0.094 32 to 0.660 2 μg.The average recovery was 100.29% and RSD was 0.58%. Conclusion: The method was pertinence and accuracy which can be used for quality control of Niuhuang Yijin tablets.
  • 加载中
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2022) PDF downloads(266) Cited by()

Related
Proportional views

Method for quality control of Cortex Phellocienciri in Niuhuang Yijin tablets

Abstract: Objective: To develop a method to determine the content of berberine hydrochlide in Niuhuang Yijin tablets to guarantee the quality of it. Methods: The determination was performed on Kromasil C18 column(4.6×250 mm,5 μm) with the mobile phase of CH3CN(0.05 mol/L)-KH2PO4(pH 3.0±0.05,0.025 mol/L)-sodium dodecylsulfonate.The detection wavelength was 348nm. Results: The correlation coefficients was 0.999 3 when the linear range was from 0.094 32 to 0.660 2 μg.The average recovery was 100.29% and RSD was 0.58%. Conclusion: The method was pertinence and accuracy which can be used for quality control of Niuhuang Yijin tablets.

Yuan Li-xia, Wang Hong. Method for quality control of Cortex Phellocienciri in Niuhuang Yijin tablets[J]. Journal of Pharmaceutical Practice and Service, 2008, (2): 141-142,155.
Citation: Yuan Li-xia, Wang Hong. Method for quality control of Cortex Phellocienciri in Niuhuang Yijin tablets[J]. Journal of Pharmaceutical Practice and Service, 2008, (2): 141-142,155.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return