DENG Yu-Lin, TANG Lei, JIANG Chun-Xia, LI Huan-Huan, ZHANG Chun. Determination of procaine hydrochloride in cardiac standstill solution by ultraviolet spectrophotometry[J]. Journal of Pharmaceutical Practice and Service, 2007, (5): 328-330.
Citation: DENG Yu-Lin, TANG Lei, JIANG Chun-Xia, LI Huan-Huan, ZHANG Chun. Determination of procaine hydrochloride in cardiac standstill solution by ultraviolet spectrophotometry[J]. Journal of Pharmaceutical Practice and Service, 2007, (5): 328-330.

Determination of procaine hydrochloride in cardiac standstill solution by ultraviolet spectrophotometry

  • Received Date: 2006-09-22
  • Objective :To establish a method for the determination of the content of procaine hydrochloride in cradiac standstill solution. Method:Ultraviolet spectrophotometric method was used to directly determine the content of procaine hydrochloride.The wavelength of detection was 290nm. Results :The liner range was 0.5~8μg/mL(r=0.999 9).The relative recovery of the method was 98.59% with RSD of 0.033%. Conclusions : This method is simple,rapid,accurate and can be used to determine the content of procaine hydrochloride in the preparation.
  • 加载中
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2880) PDF downloads(30) Cited by()

Related
Proportional views

Determination of procaine hydrochloride in cardiac standstill solution by ultraviolet spectrophotometry

Abstract: Objective :To establish a method for the determination of the content of procaine hydrochloride in cradiac standstill solution. Method:Ultraviolet spectrophotometric method was used to directly determine the content of procaine hydrochloride.The wavelength of detection was 290nm. Results :The liner range was 0.5~8μg/mL(r=0.999 9).The relative recovery of the method was 98.59% with RSD of 0.033%. Conclusions : This method is simple,rapid,accurate and can be used to determine the content of procaine hydrochloride in the preparation.