Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

ZHANG Guang-chun, ZHAO Xin, WANG Xu-ming, CHEN Jun. Determination of chlorogenic acid in Yanshu Tangjiang by high performance liquid chromatography[J]. Journal of Pharmaceutical Practice and Service, 2004, (4): 228-230.
Citation: ZHANG Guang-chun, ZHAO Xin, WANG Xu-ming, CHEN Jun. Determination of chlorogenic acid in Yanshu Tangjiang by high performance liquid chromatography[J]. Journal of Pharmaceutical Practice and Service, 2004, (4): 228-230.

Determination of chlorogenic acid in Yanshu Tangjiang by high performance liquid chromatography

  • Received Date: 2004-01-01
  • Objective To develop a method for determination of chlorogenic acid in Yanshu Tangjiang by high performance liquid chromatography. Methods ODS C18 (4.6mm×250mm, 7μm) was selected and the mobile phase consisted of acetonitrile -0.4% phosphoric acid (15:85)at the flow rate 1mL/min. The detection wavelength was 327nm. ResultsThe calibration curve was linear in the range of 1.62-21.60μg(r =1.0000). The average recovery of the method was 100.1%,RSD was 0.80% (n = 5). Conclusion This method was reliable and accurate. The method can be used to control the quality of preparation.
  • 加载中
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2215) PDF downloads(345) Cited by()

Related
Proportional views

Determination of chlorogenic acid in Yanshu Tangjiang by high performance liquid chromatography

Abstract: Objective To develop a method for determination of chlorogenic acid in Yanshu Tangjiang by high performance liquid chromatography. Methods ODS C18 (4.6mm×250mm, 7μm) was selected and the mobile phase consisted of acetonitrile -0.4% phosphoric acid (15:85)at the flow rate 1mL/min. The detection wavelength was 327nm. ResultsThe calibration curve was linear in the range of 1.62-21.60μg(r =1.0000). The average recovery of the method was 100.1%,RSD was 0.80% (n = 5). Conclusion This method was reliable and accurate. The method can be used to control the quality of preparation.

ZHANG Guang-chun, ZHAO Xin, WANG Xu-ming, CHEN Jun. Determination of chlorogenic acid in Yanshu Tangjiang by high performance liquid chromatography[J]. Journal of Pharmaceutical Practice and Service, 2004, (4): 228-230.
Citation: ZHANG Guang-chun, ZHAO Xin, WANG Xu-ming, CHEN Jun. Determination of chlorogenic acid in Yanshu Tangjiang by high performance liquid chromatography[J]. Journal of Pharmaceutical Practice and Service, 2004, (4): 228-230.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return