Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

ZHAO Ping-ge. Determination of scopolamine hydrobromide injection by ion-pair RP-HPLC[J]. Journal of Pharmaceutical Practice and Service, 2004, (3): 165-166.
Citation: ZHAO Ping-ge. Determination of scopolamine hydrobromide injection by ion-pair RP-HPLC[J]. Journal of Pharmaceutical Practice and Service, 2004, (3): 165-166.

Determination of scopolamine hydrobromide injection by ion-pair RP-HPLC

  • Received Date: 2004-01-10
  • Objective To establish a method to determinate scopolamine hydrobromide injection by ion pair RP-HPLC.Methods The mobile phase of methanol-20mmol/L sodium heptanesulfonate solution acetic acid (50:50:2) and ZORBAX SB-C18 column (4.6×250mm,5μm)was used,the flow rate was 0.9mL/min and the detect wavelength was 225nm.Results The linear range of scopolaminc hydrobromide was 0.1~0.5mg/mL(r=0.9999). The average recovery was 100.15%,RSD was 1.58%.Conclusion The method was simple,rapid and accurate. It can be used to control the quality of scopolamine hydrobromide injection.
  • 加载中
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2470) PDF downloads(1064) Cited by()

Related
Proportional views

Determination of scopolamine hydrobromide injection by ion-pair RP-HPLC

Abstract: Objective To establish a method to determinate scopolamine hydrobromide injection by ion pair RP-HPLC.Methods The mobile phase of methanol-20mmol/L sodium heptanesulfonate solution acetic acid (50:50:2) and ZORBAX SB-C18 column (4.6×250mm,5μm)was used,the flow rate was 0.9mL/min and the detect wavelength was 225nm.Results The linear range of scopolaminc hydrobromide was 0.1~0.5mg/mL(r=0.9999). The average recovery was 100.15%,RSD was 1.58%.Conclusion The method was simple,rapid and accurate. It can be used to control the quality of scopolamine hydrobromide injection.

ZHAO Ping-ge. Determination of scopolamine hydrobromide injection by ion-pair RP-HPLC[J]. Journal of Pharmaceutical Practice and Service, 2004, (3): 165-166.
Citation: ZHAO Ping-ge. Determination of scopolamine hydrobromide injection by ion-pair RP-HPLC[J]. Journal of Pharmaceutical Practice and Service, 2004, (3): 165-166.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return