YANG Xi-Xiang, GU Li. The improve of the method for determination compound fluocinonide ointment[J]. Journal of Pharmaceutical Practice and Service, 2002, (3): 171-173.
Citation: YANG Xi-Xiang, GU Li. The improve of the method for determination compound fluocinonide ointment[J]. Journal of Pharmaceutical Practice and Service, 2002, (3): 171-173.

The improve of the method for determination compound fluocinonide ointment

  • Received Date: 2002-01-15
  • OBJECTIVE To improve the method for determination compound fluocinonide ointment.METHODS A method of RP HPLC be used, plus the internal standard after extraction and filter.ODS column (250mm×4.6mm, 5μm) was selected and the mobile phase was consisted of methanol-water-ether(62:38:2,v/v/v) at flow rate of 1.0ml·min-1.The detection wavelength was 240nm.RESULTS The precision and the accuracy of improved method are good.CONCLUSION The problem of the old method was solved with this improved method and have a universal significance for the determination of ointment preparation.
  • 加载中
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2301) PDF downloads(1028) Cited by()

Related
Proportional views

The improve of the method for determination compound fluocinonide ointment

Abstract: OBJECTIVE To improve the method for determination compound fluocinonide ointment.METHODS A method of RP HPLC be used, plus the internal standard after extraction and filter.ODS column (250mm×4.6mm, 5μm) was selected and the mobile phase was consisted of methanol-water-ether(62:38:2,v/v/v) at flow rate of 1.0ml·min-1.The detection wavelength was 240nm.RESULTS The precision and the accuracy of improved method are good.CONCLUSION The problem of the old method was solved with this improved method and have a universal significance for the determination of ointment preparation.

YANG Xi-Xiang, GU Li. The improve of the method for determination compound fluocinonide ointment[J]. Journal of Pharmaceutical Practice and Service, 2002, (3): 171-173.
Citation: YANG Xi-Xiang, GU Li. The improve of the method for determination compound fluocinonide ointment[J]. Journal of Pharmaceutical Practice and Service, 2002, (3): 171-173.

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return