Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

DU Yi, CHEN Lei, LI Ling, Zhou Jin, LÜ Lei. Residue detection of DMAP and DCC in docetaxel by GC-MS[J]. Journal of Pharmaceutical Practice and Service, 2018, 36(5): 446-449. doi: 10.3969/j.issn.1006-0111.2018.05.014
Citation: DU Yi, CHEN Lei, LI Ling, Zhou Jin, LÜ Lei. Residue detection of DMAP and DCC in docetaxel by GC-MS[J]. Journal of Pharmaceutical Practice and Service, 2018, 36(5): 446-449. doi: 10.3969/j.issn.1006-0111.2018.05.014

Residue detection of DMAP and DCC in docetaxel by GC-MS

doi: 10.3969/j.issn.1006-0111.2018.05.014
  • Received Date: 2018-03-07
  • Rev Recd Date: 2018-04-13
  • Objective To establish a GC-MS method for residue detection of 4-Dimethylaminopyridine (DMAP) and Dicyclohexyl Carbodiimide (DCC) in docetaxel. Methods The separation was performed on an Agilent DB-5msUI capillary column (30 m×0.25 mm, 0.25 μm) with programmed temperature. The carrier gas was high purity helium, the flow rate was 1.5 ml/min and the injection volume was 1 μl. Electron impact ion source (EI) and selection monitoring mode (SIM) were applied for quantitative analysis. The quantitative ion of DMAP, DCC and internal standard (IS) was 121, 163 and 95 respectively. Docetaxel was ultrasonically extracted with methanol. Results The calibration of DMAP and DCC showed good linear relationship (r>0.999 2), the limits of quantification (LOQ) were 50.90 ng/ml and 10.21 ng/ml separately. Intra-day and inter-day precision were all less than 5% and recoveries were more than 90%, which conformed with the requirement of methodology validation. No residues of DMAP and DCC were detected in three batches of samples. Conclusion The method was sensitive and selective which can be used for the detection of trace impurities in docetaxel.
  • [1] 徐少杰,袁建勇,周辉,等. 多西他赛合成工艺[J]. 科技导报, 2010, 28(13):82-86.
    [2] 孟秀敏. 多西他赛联合卡培他滨治疗紫杉醇耐药乳腺癌患者40例[J]. 中国药业, 2013, 22(17):64-65.
    [3] 黄和,李丕宏,张毅,等. 多西他赛联合奥沙利铂及氟尿嘧啶治疗晚期胃癌临床观察[J]. 浙江医学, 2011, 33(2):183-185.
    [4] 朱庆华,张国兵. 多西他赛与奈达铂联合治疗晚期非小细胞肺癌的临床疗效观察[J]. 中国现代医生, 2015, 53(20):89-92.
    [5] 孙继国,周自成,夏玲远. 4-二甲氨基吡啶(DMAP)在医药合成中的应用[J]. 沧州师范学院学报, 2014, 30(1):49-53.
    [6] WIKIPEDIA. DMAP. Wikipedia website (2016). (2016-09-18).[2018-03-07]. https://en.wikipedia.org/wiki/4-Dimethylaminopyridine.
    [7] SAVJANI JK, MULAMKATTIL S, VARIYA B, et al. Molecular docking, synthesis and biological screening of mefenamic acid derivatives as anti-inflammatory agents[J]. Eur J Pharmacol, 2017, 801:28-34.
    [8] 薄采颖,毕良武,王玉民,等. DCC及其在有机合成中的应用[J]. 化工时刊, 2007, 21(10):4-6.
    [9] 范小振,张小杰,徐宝军. 高效液相色谱法测定烯草酮合成废液中4-二甲氨基吡啶含量[J]. 化学研究与应用, 2015, 27(2):237-239.
    [10] 刘义国,郝文明. 气相色谱法分析N,N'-二环己基碳二亚胺的纯度[J]. 山东化工, 1998, 27(5):39-40.
  • 加载中
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(4716) PDF downloads(525) Cited by()

Related
Proportional views

Residue detection of DMAP and DCC in docetaxel by GC-MS

doi: 10.3969/j.issn.1006-0111.2018.05.014

Abstract: Objective To establish a GC-MS method for residue detection of 4-Dimethylaminopyridine (DMAP) and Dicyclohexyl Carbodiimide (DCC) in docetaxel. Methods The separation was performed on an Agilent DB-5msUI capillary column (30 m×0.25 mm, 0.25 μm) with programmed temperature. The carrier gas was high purity helium, the flow rate was 1.5 ml/min and the injection volume was 1 μl. Electron impact ion source (EI) and selection monitoring mode (SIM) were applied for quantitative analysis. The quantitative ion of DMAP, DCC and internal standard (IS) was 121, 163 and 95 respectively. Docetaxel was ultrasonically extracted with methanol. Results The calibration of DMAP and DCC showed good linear relationship (r>0.999 2), the limits of quantification (LOQ) were 50.90 ng/ml and 10.21 ng/ml separately. Intra-day and inter-day precision were all less than 5% and recoveries were more than 90%, which conformed with the requirement of methodology validation. No residues of DMAP and DCC were detected in three batches of samples. Conclusion The method was sensitive and selective which can be used for the detection of trace impurities in docetaxel.