Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

JIN Weihua, CHEN Hua, ZHANG Ming, PU Zhiqiang. Comparision two kinds of content determination method of mannatide for injection[J]. Journal of Pharmaceutical Practice and Service, 2016, 34(1): 62-65. doi: 10.3969/j.issn.1006-0111.2016.01.017
Citation: JIN Weihua, CHEN Hua, ZHANG Ming, PU Zhiqiang. Comparision two kinds of content determination method of mannatide for injection[J]. Journal of Pharmaceutical Practice and Service, 2016, 34(1): 62-65. doi: 10.3969/j.issn.1006-0111.2016.01.017

Comparision two kinds of content determination method of mannatide for injection

doi: 10.3969/j.issn.1006-0111.2016.01.017
  • Received Date: 2014-12-12
  • Rev Recd Date: 2015-04-14
  • Objective To compare two methods in the determination of mannatide for injection. Methods The contents were determined by spectrophotometry and HPLC method. Results In the samples determined by Spectrophotometric Determination,soluble in phenol solution and sulfuric acid, was detected at wavelength 490 nm, D-mannose derivatives linear concentration range is 10.2-51 μg/ml (r=0.999 1), the average content was 92.14%, the average RSD value was 1.17%. In the HPLC determination, with color spectrum column: Gemini C18 (250 mm×4.6 mm, 5 μm), mobile phase acetonitrile -0.02 mol/L ammonium acetate solution (20:80), flow rate:1 ml/min, the detection wavelength was at 250 nm, column temperature: 30 ℃, sample size: 10 μl detection. The average content ws 83.47%, the average RSD value was 0.65%, the content of two kinds of methods could effectively determine the D-mannose. Conclusion The average content for spectrophotometry was higher, but the phenol was used in detection of special odor, poisonous, corrosive, would cause a certain risk.HPLC was exclusive,chromatogram was more intuitive, on the operator harmfulness and less irritating. A new method for the determination of D-mannose was established at the same time.
  • [1] 陈立江,王 菁,刘 宇,等.南瓜多糖含量测定方法比较[J].辽宁大学学报,2014,41(1):76-81.
    [2] 钟方晓,任海华,李 岩. 多糖含量测定方法比较[J].时珍国医国药,2007,18(8):1916-1917.
    [3] 冯泽岸,巩慧敏,邵婷玑,等. 南沙参中多糖含量测定方法的建立及比较[J].中国药师,2012,15(3):290-293.
    [4] 任 磊,李慧勇,张清波,等. 苯酚硫酸法定量测定桔梗流浸膏中多糖的研究[J].黑龙江医药,2014,27(2):227-230.
    [5] 方崇波,赵夏雨,吴巧凤. 苯酚硫酸法测定猕猴桃多糖注射剂中多糖的含量[J].海峡药学,2010,22(10):64-66.
    [6] 刘立超,黄洪林,赖正权,等. 苯酚硫酸法测定栀子水溶性多糖含量[J].安徽医药,2005,9(11):831-832.
    [7] 章乐建,泮玉华,赵颖飞. 高效液相色谱法测定乐清栽培的铁皮石斛不同年份甘露糖的含量[J].海峡药学,2012,24(3):79-80.
    [8] 毛幼儿,周桂芬. 基于柱前衍生化HPLC法分析铁皮石斛茎和叶多糖中甘露糖的含量[J].江西中医学院学报,2011,23(4):38-39.
    [9] Sato T, Katayama K, Arai T, et al. Simultaneous determination of serum mannose and glucose concentrations in dog serum using high performance liquid chromatography[J]. Res Vet Sci,2008,84(1):26-29.
    [10] 郝桂堂, 陈尚卫, 朱 松,等.对氨基苯甲酸衍生化高效液相色谱法分析多糖中的单糖及糖醛酸组成[J].色谱,2007,25(1):75-79.
    [11] 金伟华,陈 华,张 明,等.甘露聚糖肽滴鼻液的制备及其质量控制[J].中国药房,2014,25(9):828-830.
  • 加载中
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(3473) PDF downloads(116) Cited by()

Related
Proportional views

Comparision two kinds of content determination method of mannatide for injection

doi: 10.3969/j.issn.1006-0111.2016.01.017

Abstract: Objective To compare two methods in the determination of mannatide for injection. Methods The contents were determined by spectrophotometry and HPLC method. Results In the samples determined by Spectrophotometric Determination,soluble in phenol solution and sulfuric acid, was detected at wavelength 490 nm, D-mannose derivatives linear concentration range is 10.2-51 μg/ml (r=0.999 1), the average content was 92.14%, the average RSD value was 1.17%. In the HPLC determination, with color spectrum column: Gemini C18 (250 mm×4.6 mm, 5 μm), mobile phase acetonitrile -0.02 mol/L ammonium acetate solution (20:80), flow rate:1 ml/min, the detection wavelength was at 250 nm, column temperature: 30 ℃, sample size: 10 μl detection. The average content ws 83.47%, the average RSD value was 0.65%, the content of two kinds of methods could effectively determine the D-mannose. Conclusion The average content for spectrophotometry was higher, but the phenol was used in detection of special odor, poisonous, corrosive, would cause a certain risk.HPLC was exclusive,chromatogram was more intuitive, on the operator harmfulness and less irritating. A new method for the determination of D-mannose was established at the same time.

JIN Weihua, CHEN Hua, ZHANG Ming, PU Zhiqiang. Comparision two kinds of content determination method of mannatide for injection[J]. Journal of Pharmaceutical Practice and Service, 2016, 34(1): 62-65. doi: 10.3969/j.issn.1006-0111.2016.01.017
Citation: JIN Weihua, CHEN Hua, ZHANG Ming, PU Zhiqiang. Comparision two kinds of content determination method of mannatide for injection[J]. Journal of Pharmaceutical Practice and Service, 2016, 34(1): 62-65. doi: 10.3969/j.issn.1006-0111.2016.01.017
Reference (11)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return