Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

QIAN Xian, ZHAO Liang, LU Lei, ZHANG Hai, LI Yueyue, ZHANG Guoqing. Research progress in steroid hormone analysis in vivo by chromatography-mass spectrometry[J]. Journal of Pharmaceutical Practice and Service, 2014, 32(3): 176-180,190. doi: 10.3969/j.issn.1006-0111.2014.03.004
Citation: QIAN Xian, ZHAO Liang, LU Lei, ZHANG Hai, LI Yueyue, ZHANG Guoqing. Research progress in steroid hormone analysis in vivo by chromatography-mass spectrometry[J]. Journal of Pharmaceutical Practice and Service, 2014, 32(3): 176-180,190. doi: 10.3969/j.issn.1006-0111.2014.03.004

Research progress in steroid hormone analysis in vivo by chromatography-mass spectrometry

doi: 10.3969/j.issn.1006-0111.2014.03.004
  • Received Date: 2013-08-28
  • Rev Recd Date: 2014-01-14
  • Steroid hormones were chemical compounds of high efficiency, which played a significant role in various physiological activities. However, the concentrations of hormones in vivo were extremely low, so it was very important for their accurate quantification. Chromatography-mass spectrometry technology was widely employed because of advances in high efficient, rapid and sensitive. The application of steroid hormone analysis by chromatography-mass spectrometry was reviewed in this paper, which could provide reference for furthuer clinical research.
  • [1] Holst JP,Soldin OP,Guo T,et al. Steroid hormones: relevance and measurement in the clinical laboratory[J].Clin Lab Med,2004,24(1):105-118.
    [2] Dorgan JF,Fears TR,McMahon RP,et al. Measurement of steroid sex hormones in serum: a comparison of radioimmunoassay and mass spectrometry[J].Steroids,2002,67(3-4):151-158.
    [3] Carter GD,Carter R,Jones J,et al. How accurate are assays for 25-hydroxyvitamin D-Data from the international vitamin D external quality assessment scheme[J].Clin Chem,2004,50(11):2195-2197.
    [4] Hollis BW,Kamerud JQ,Kurkowski A,et al. Quantification of circulating 1,25-dihydroxyvitamin D by radioimmunoassay with 125 I-labeled tracer[J].Clin Chem,1996,42(4):586-592.
    [5] Hsing AW,Stanczyk FZ,Belanger A,et al. Reproducibility of serum sex steroid assays in men by RIA and mass spectrometry[J].Cancer Epidemiol Biomarkers Prev,2007,16(5):1004-1008.
    [6] Poulson K,Sancho J,Haber E. A simplified radioimmunoassay for plasma aldosterone employing an antibody of unique specificity[J].Clin Immunol,1974,2(3):373-380.
    [7] Schioler V,Thode J. Six direct radioimmunoassays of estradiol evaluated[J].Clin Chem,1988,34(5):949-952.
    [8] Xu X,Roman JM,Issaq HJ,et al.Quantitative measurement of endogenous estrogens and estrogen metabolites in human serum by liquid chromatography-tandem mass spectrometry[J].Anal Chem,2007,79(20):7813-7821.
    [9] Santen RJ,Demers L,Ohorodnik S,et al. Superiority of gas chromatography/tandem mass spectrometry assay (GC/MS/MS) for estradiol for monitoring of aromatase inhibitor therapy[J].Steroids,2007,72(8):666-671.
    [10] Wolthers BG,Kraan GP. Clinical applications of gas chromatography and gas chromatographymass spectrometry of steroids[J].J Chromatogr A,1999,843(1-2):247-274.
    [11] Draisci R,Palleschi L,Ferretti E,et al.Quantitation of anabolic hormones and their metabolites in bovine serum and urine by liquid chromatography-tandem mass spectrometry[J].J Chromatogr A,2000,870(1-2):511-522.
    [12] Guo T,Chan M,Soldin SJ. Steroid profiles using liquid chromatography-tandem mass spectrometry with atmospheric pressure photoionization source[J].Arch Pathol Lab Med,2004,128(4):469-475.
    [13] Guo T,Gu J,Soldin OP,et al.Rapid measurement of estrogens and their metabolites in human serum by liquid chromatographytandem mass spectrometry without derivatization[J].Clin Biochem,2008,41(9):736-741.
    [14] Nelson RE,Grebe SK,Kane DJ,et al. Liquid chromatography-tandem mass spectrometry assay for simultaneous measurement of estradiol and estrone in human plasma[J].Clin Chem,2004,50(2):373-384.
    [15] Guo T,Taylor RL,Singh RJ,et al. Simultaneous determination of 12 steroids by isotope dilution liquid chromatography-photospray ionization tandem mass spectrometry[J].Clin Chim Acta,2006,372(1-2):76-82.
    [16] Andrew R. Clinical measurement of steroid metabolism[J].Best Pract Res Clin Endocrinol Metab,2001,15(1):1-16.
    [17] Abraham GE. Solid-phase radioimmunoassay of 17β-estradiol[J].J Clin Endocrinol Metab, 1969,29(6):866-870.
    [18] Rahkonena PK,Huhtinenb K,Poutanenb M,et al. Fast and sensitive liquid chromatography-mass spectrometry assay for seven androgenic and progestagenic steroids in human serum[J].J Steroid Biochem Mol Biol,2011,127(3-5):396-404.
    [19] Rothman MS,Carlson NE,Xu M,et al. Reexamination of testosterone, dihydrotestosterone, estradiol and estrone levels across the menstrual cycle and in postmenopausal women measured by liquid chromatography-tandem mass spectrometry[J].Steroids,2011,76(1-2):177-182.
    [20] Kushnir MM,Rockwood AL,Roberts WL,et al. Development and performance evaluation of a tandem mass spectrometry assay for 4 adrenal steroids[J].Clin Chem,2006,52(8):1559-1567.
    [21] Carvalho VM,Nakamura OH,Vieira JG. Simultaneous quantitation of seven endogenous C-21 adrenal steroids by liquid chromatography tandem mass spectrometry in human serum[J].J Chromatogr B Analyt Technol Biomed Life Sci,2008,872(1-2):154-161.
    [22] McWhinney BC,Briscoe SE,Ungerer JP. Pretorius CJ.Measurement of cortisol, cortisone, prednisolone, dexamethasone and 11-deoxycortisol with ultra high performance liquid chromatography-tandem mass spectrometry: application for plasma, plasma ultrafiltrate, urine and saliva in a routine laboratory[J].J Chromatogr B Analyt Technol Biomed Life Sci,2010,878(28):2863-2869.
    [23] Rauh M,Gröschl M,Rascher W,et al.Automated, fast and sensitive quantification of 17 alpha-hydroxy-progesterone, androstenedione and testosteroneby tandem mass spectrometry with on-line extraction[J].Steroids,2006,71(6):450-458.
    [24] Shackleton CH. Mass spectrometry: application to steroid and peptide research[J].Endocr Rev,1985,6(3):441-486.
    [25] Hansen M,Jacobsen NW,Nielsen FK,et al. Determination of steroid hormones in blood by GC-MS/MS[J]. Anal Bioanal Chem,2011,400(10):3409-3417.
    [26] Courant F,Aksglaede L,Antignac JP,et al. Assessment of circulating sex steroid levels in prepubertal and pubertal boys and girls by a novel ultrasensitive gas chromatography-tandem mass spectrometry method [J].J Steroid Biochem Mol Biol,2010,95(1):82-92.
    [27] Steven JS,Soldin OP. Steroid hormone analysis by tandem mass spectrometry[J].Clin Chem,2009,55(6):1061-1066.
    [28] McDonald JG,Matthew S,Richard J. Steroid profiling by gas chromatography-mass spectrometry and high performance liquid chromatography-mass spectrometry for adrenal diseases[J].Horm Cancer,2011,2(6):324-332.
    [29] Kushnir MM,Rockwood AL,William L,et al. Liquid chromatography tandem mass spectrometry for analysis of steroids in clinical laboratories[J].Clin Biochem,2011,44 (1):77-88.
    [30] Koal T,Schmiederer D,Rauh M. Standardized LC-MS/MS based steroid hormone profile-analysis[J].J Steroid Biochem Mol Biol,2012,129(3-5):129-138.
    [31] Naessen T,Sjogren U,Bergquist J,et al. Endogenous steroids measured by high-specificity liquid chromatography-tandem mass spectrometry and prevalent cardiovascular disease in 70-year-old men and women[J].J Clin Endocrinol Metab,2010,95(4):1889-1897.
    [32] Rossi C,Calton L,Hammond G,et al. Serum steroid profiling for congenital adrenal hyperplasia using liquid chromatography-tandem mass spectrometry[J].Clin Chim Acta,2010,411(3-4):222-228.
    [33] Kulle AE,Riepe FG,Melchior D,et al. A novel ultrapressure liquid chromatography tandem mass spectrometry method for the simultaneous determination of androstenedione, testosterone, and dihydrotestosterone in pediatric blood samples: age-and sex-specific reference data[J].J Clin Endocrinol Metab,2010,95(5):2399-2409.
    [34] Rousu T,Tolonen A. Comparison of unit resolution SRM and TOF-MS at 12,000 mass resolution for quantitative bioanalysis of 11 steroids from human plasma[J].Bioanalysis,2012,4(5):555-563.
    [35] Ceglarek U,Kortz L,Leichtle A,et al. Rapid quantification of steroid patterns in human serum by on-line solid phase extraction combined with liquid chromatography-triple quadrupole linear ion trap mass spectrometry[J].Clin Chim Acta,2009,401(1-2):114-118.
    [36] Higashi T,Shimada K. Derivatization of neutral steroids to enhance their detection characteristics in liquid chromatography-mass spectrometry[J].Anal Bioanal Chem,2004,378(4):875-882.
    [37] Maidana P, Bruno OD, Mesch V. A critical analysis of cortisol measurements: an update[J]. Medicina (B Aires),2013,73(6):579-584.
  • 加载中
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(3925) PDF downloads(341) Cited by()

Related
Proportional views

Research progress in steroid hormone analysis in vivo by chromatography-mass spectrometry

doi: 10.3969/j.issn.1006-0111.2014.03.004

Abstract: Steroid hormones were chemical compounds of high efficiency, which played a significant role in various physiological activities. However, the concentrations of hormones in vivo were extremely low, so it was very important for their accurate quantification. Chromatography-mass spectrometry technology was widely employed because of advances in high efficient, rapid and sensitive. The application of steroid hormone analysis by chromatography-mass spectrometry was reviewed in this paper, which could provide reference for furthuer clinical research.

QIAN Xian, ZHAO Liang, LU Lei, ZHANG Hai, LI Yueyue, ZHANG Guoqing. Research progress in steroid hormone analysis in vivo by chromatography-mass spectrometry[J]. Journal of Pharmaceutical Practice and Service, 2014, 32(3): 176-180,190. doi: 10.3969/j.issn.1006-0111.2014.03.004
Citation: QIAN Xian, ZHAO Liang, LU Lei, ZHANG Hai, LI Yueyue, ZHANG Guoqing. Research progress in steroid hormone analysis in vivo by chromatography-mass spectrometry[J]. Journal of Pharmaceutical Practice and Service, 2014, 32(3): 176-180,190. doi: 10.3969/j.issn.1006-0111.2014.03.004
Reference (37)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return