Message Board

Respected readers, authors and reviewers, you can add comments to this page on any questions about the contribution, review,        editing and publication of this journal. We will give you an answer as soon as possible. Thank you for your support!

Name
E-mail
Phone
Title
Content
Verification Code

ZHANG Juan-juan, ZHU Quan-gang, ZHANG Li-chao. Effect of different density microneedle-roller on transdermal delivery of triamcinolone acetonide[J]. Journal of Pharmaceutical Practice and Service, 2013, 31(6): 415-417,461. doi: 10.3969/j.issn.1006-0111.2013.06.005
Citation: ZHANG Juan-juan, ZHU Quan-gang, ZHANG Li-chao. Effect of different density microneedle-roller on transdermal delivery of triamcinolone acetonide[J]. Journal of Pharmaceutical Practice and Service, 2013, 31(6): 415-417,461. doi: 10.3969/j.issn.1006-0111.2013.06.005

Effect of different density microneedle-roller on transdermal delivery of triamcinolone acetonide

doi: 10.3969/j.issn.1006-0111.2013.06.005
  • Received Date: 2013-03-22
  • Rev Recd Date: 2013-05-14
  • Objective To study the effects of different density microneedle-roller arrays on transdermal delivery of triamcinolone acetonide. Methods The in vitro permeation characteristics through isolated nude mouse skin were studied by modified Franz diffusion cells. Levels in the receptor solution of the control group, the 192 needles microneedle rooler group and the 540 needles microneedle rooler group were measured by HPLC at 2、4、6、8、10 and 12 h, and sampling volume was 0.2 ml. The accumulative penetration amount were counted and the level of triamcinolone acetonide in skin were determined. Plasma concentrations of triamcinolone acetonide and skin volume were measured 2 hours later after administration by HPLC to observe the penetration of triamcinolone acetonide in vivo. Results Different density microneedle-roller could promote the transdermal delivery of triamcinolone acetonide respectively. Transdermal experiment results showed that the cumulative infiltration volume of 192 needles group was about 1.3 times of the control samples, and 540 needles was 2.2 times. Accordingly, skin retention volume were1.9times and 2.8 times of the control group respectively. In vivo results showed that skin retention volume were 2.1 times and 2.3 times of control group, while triamcinolone acetonide in plasma were 1.3 times and 1.4 times of control group. Conclusion Microneedles could effectively promote the skin permeability and deposition of triamcinolone acetonide, and triamcinolone acetonide in plasma was increased at the same time. The promoting of different density was diverse.
  • [1] 黄兴汉,费路华,陈春游.HPLC法测定复方醋酸曲安奈德乳膏的含量[J]. 中国药师,2011,14(1):90.
    [2] 胡斌,林彩,赵映兰,等.高效液相色谱法测定复方醋酸曲安奈德溶液中醋酸曲安奈德含量[J]. 中国药业,2010,19(21):26.
    [3] 谢俊,王宇,张晓龙,等.曲安奈德治疗增生性瘢痕的疗效观察[J]. 临床医学与护理研究,2006,5(6):16,33.
    [4] 董洪峰,刘倩,邹敏. 曲安奈德治疗瘢痕疙瘩28例[J]. 现代临床医学,2006,34(6):443.
    [5] 潘志斌.微针技术的研究进展[J]. 中国新药与临床杂志,2005,24(11):912.
    [6] You SK,Noh YW, Park HH,et al. Effect of applying modes of the polymer microneedle-roller on the permeation of L-ascorbic acid in rats[J]. J Drug Target,2010,18(1):15.
    [7] Zhou CP, Liu YL, Wang HL,et al. Transdermal delivery of insulin using microneedle rollers in vivo[J]. Int J Pharm,2010,392(1-2):127.
    [8] 胡守莲,范玉峰,李道明.高效液相色谱法测定醋酸曲安奈德尿素乳膏中醋酸曲安奈德的含量[J]. 中国医药导报,2009,6(27):53.
    [9] 陈浩,孙树茂,秦晓怡,等.高效液相色谱法检测兔血浆中曲安奈德的浓度[J]. 中国医院药学杂志,2009,29(19):1614.
    [10] Liu W, Hu ML, Liu WS, et al. Investigation of the carbopol gel of solid lipid nanoparticles for the transdermal iontophoretic delivery of triamcinolone acetonide acetate[J]. Int J Pharm,2008, 364:135.
    [11] Vieira MLT, Singha RP, Derendorf H. Simultaneous HPLC analysis of triamcinolone acetonide and budesonide in microdialysate and rat plasma:Application to a pharmacokinetic study[J]. J Chromatogr B, 2010,878:2967.
    [12] 邱凯锋,劳贺存,陈露诗,等. 曲安奈德经皮渗透特性研究[J]. 今日药学,2011,21(08):475.
  • 加载中
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2862) PDF downloads(273) Cited by()

Related
Proportional views

Effect of different density microneedle-roller on transdermal delivery of triamcinolone acetonide

doi: 10.3969/j.issn.1006-0111.2013.06.005

Abstract: Objective To study the effects of different density microneedle-roller arrays on transdermal delivery of triamcinolone acetonide. Methods The in vitro permeation characteristics through isolated nude mouse skin were studied by modified Franz diffusion cells. Levels in the receptor solution of the control group, the 192 needles microneedle rooler group and the 540 needles microneedle rooler group were measured by HPLC at 2、4、6、8、10 and 12 h, and sampling volume was 0.2 ml. The accumulative penetration amount were counted and the level of triamcinolone acetonide in skin were determined. Plasma concentrations of triamcinolone acetonide and skin volume were measured 2 hours later after administration by HPLC to observe the penetration of triamcinolone acetonide in vivo. Results Different density microneedle-roller could promote the transdermal delivery of triamcinolone acetonide respectively. Transdermal experiment results showed that the cumulative infiltration volume of 192 needles group was about 1.3 times of the control samples, and 540 needles was 2.2 times. Accordingly, skin retention volume were1.9times and 2.8 times of the control group respectively. In vivo results showed that skin retention volume were 2.1 times and 2.3 times of control group, while triamcinolone acetonide in plasma were 1.3 times and 1.4 times of control group. Conclusion Microneedles could effectively promote the skin permeability and deposition of triamcinolone acetonide, and triamcinolone acetonide in plasma was increased at the same time. The promoting of different density was diverse.

ZHANG Juan-juan, ZHU Quan-gang, ZHANG Li-chao. Effect of different density microneedle-roller on transdermal delivery of triamcinolone acetonide[J]. Journal of Pharmaceutical Practice and Service, 2013, 31(6): 415-417,461. doi: 10.3969/j.issn.1006-0111.2013.06.005
Citation: ZHANG Juan-juan, ZHU Quan-gang, ZHANG Li-chao. Effect of different density microneedle-roller on transdermal delivery of triamcinolone acetonide[J]. Journal of Pharmaceutical Practice and Service, 2013, 31(6): 415-417,461. doi: 10.3969/j.issn.1006-0111.2013.06.005
Reference (12)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return